Cable Wholesale UL2405 Electrical Cable 2 Core 3 Core 2.5mm Wire Cable
Maximum Resistance at 20ºCΩ/kmAWGNo./mmDia.mmNom. Thick.mmNom.Dia.mmBraid ShieldNo./No./mmNom. Thick.mmNom.Dia.mm2307/0.10.300.411.1256/0.120.453.38354287/0.1270.380.411.2060/0.120.453.54223267/0.160.480.431.3457/0.120.453.821392411/0.160.610.411.4371/0.120.454.0088.92217/0.160.760.431.62
-
UL3132 Silicone Wire 18 AWG 24 AWG Stranded Copper Electric Wire Cable for House
Overall Diameter(mm)Nom.Min.Nom.Tol.167/0.4914.601.500.400.332.30±0.10187/0.3923.201.190.400.331.97±0.10207/0.3036.700.920.460.331.85±0.102217/0.1659.400.760.460.331.70±0.10227/0.25459.400.760.460.331.70±0.10221/0.65 556.400.650.460.331.57±0.1024133/0.0594.2
-
JIS Flexible Cord Lead Free PVC Insulated Jacketed Power Cable Wire Single Core 2 Core 3 Core
Maximum Resistance at 20ºCΩ/kmCross Section mm²NO./mmDia.mmNom. Thick.mmNom. Dia.mmNom. Thick.mmNom. Dia.mmVSF10.7530/0.1801.100.802.70--24.4HVSF0.520/0.1800.930.812.55--40.1HVSF0.7530/0.1801.100.802.70--24.4HVSF1.2550/0.1801.470.823.10--15.1HVSF2.0037/0.2601.820.823.45--9.2HCFF0.756
-
Vertical Test Approval PVC Insulated Wire Electrical Extention Cords
Rated Temperature105ºCConductorSolid or stranded,tinned or bare copper conductor 30--2/0AWGStandardUL Subject758,UL1581,C22.2ApplicationAWGNO.of CondInsulation Thick.Outside Thick.Packingmmmmmmm/rΩ/mm307/0.10.791.90610354.33287/0.1270.792.00610223.75267/0.160.792.05610139.762411/0.160.792
-
Stranded Xlpvc Insulated Extention Cables
Rated Temperature105ºCConductorSolid or stranded,tinned or bare copper conductor 30--16AWG StandardUL Subject758,UL1581,C22.2ApplicationAWGNO.of CondInsulation Thick.Outside Thick.Packingmmmmmmm/rΩ/mm307/0.10.411.10610354.33287/0.1270.411.20610223.75267/0.160.411.30610139.762411/0.160.41
-
Thermo Plastic Heat Resistant Reinforced Hook up Wire
Rated Temperature80ºCConductorSolid or stranded,tinned or bare copper conductor 24--8AWGStandardSAE J1128ApplicationOverallDia(mm)No./mmNomMin8168/0.2543.80.550.394.9010105/0.25430.500.354.001265/0.2542.40.450.323.301441/0.2541.90.400.282.701626/0.2541.50.400.282.401816/0.2541.20.400.282.20207/
-
UL20379 Aluminum Overall Shield Bare Copper Conductor Electrical Cable
Rated Temperature80ºCConductorStranded, tinned or bare copper conductorStandardUL Subject 758, UL1581 & CSA C22.2 No.210.2ApplicationFor internal wiring or external wiring of Class 2 systems equipment and electronic equipmentMaximum Resistance at 20ºCΩ/kmAWGNo./mmNom./Dia.mmNom
-
10 Cores 28 AWG Stranded Eletrical Internal Wiring
Rated Temperature60ºCConductorStranded,tinned or bare copper, or tinsel conductorStandardUL758,UL1581,CSA C22.2 No.210.2ApplicationFor internal wiring in Class 2 circuits of electronic equipment or TV game machine data transmissionNo./mmNom. Dia.Nom.Thick.Nom.Dia.Drain WireMaterialSpiral No./mm