Cable & Wire

0.6/1kv IEC 60502 2-30 Core Cu/PVC/PVC Flame Retardant Control Cable Cvv

Henan Hongda Cable Co., Ltd.
  • Application:Construction, Underground, Industrial, Power Station
  • Voltage:Low and Medium Voltage Cable
  • Current:DC Cable
  • Insulation Material:PVC
  • Sheath Material:PVC
  • Material Shape:Round Wire

Base Info

  • Model NO.:CVV
  • Wire Core Material:Bare Copper Wire
  • Certification:ISO, CCC
  • Model:Cvv
  • Brand:Hongda
  • Transport Package:Wooden Drum
  • Specification:2-30 cores, 0.5-6mm2
  • Trademark:Hongda
  • Origin:China
  • HS Code:8544492100
  • Production Capacity:3000km,Month

Description

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
20.57/0.300.81.810.036.00.016298500/D0.757/0.370.81.810.024.50.0142110500/D17/0.400.81.810.518.10.0135115500/D1.57/0.500.81.811.012.10.0115135500/D2.57/0.670.81.812.07.410.0093180500/D47/0.851.01.814.54.610.0092255500/D67/1.041.01.815.53.080.0078320500/D


3 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
30.57/0.300.81.810.036.00.0162110500/D0.757/0.370.81.810.524.50.0142125500/D17/0.400.81.811.018.10.0135135500/D1.57/0.500.81.811.512.10.0115160500/D2.57/0.670.81.813.07.410.0093220500/D47/0.851.01.815.04.610.0092315500/D67/1.041.01.816.53.080.0078405500/D

4 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
40.57/0.300.81.811.036.00.0162130500/D0.757/0.370.81.811.524.50.0142150500/D17/0.400.81.811.518.10.0135160500/D1.57/0.500.81.812.512.10.0115195500/D2.57/0.670.81.814.07.410.0093265500/D47/0.851.01.816.54.610.0092390500/D67/1.041.01.817.03.080.0078510500/D

5 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
50.57/0.300.81.811.536.00.0162150500/D0.757/0.370.81.812.524.50.0142175500/D17/0.400.81.812.518.10.0135190500/D1.57/0.500.81.813.512.10.0115230500/D2.57/0.670.81.815.07.410.0093320500/D47/0.851.01.818.04.610.0092470500/D67/1.041.01.819.53.080.0078620500/D

6 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
60.57/0.300.81.812.536.00.0162165500/D0.757/0.370.81.813.024.50.0142190500/D17/0.400.81.813.518.10.0135205500/D1.57/0.500.81.814.512.10.0115255500/D2.57/0.670.81.816.07.410.0093355500/D47/0.851.01.819.54.610.0092525500/D67/1.041.01.821.03.080.0078690500/D

7 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
70.57/0.300.81.812.536.00.0162170500/D0.757/0.370.81.813.024.50.0142200500/D17/0.400.81.813.518.10.0135215500/D1.57/0.500.81.814.512.10.0115270500/D2.57/0.670.81.816.07.410.0093380500/D47/0.851.01.819.54.610.0092570500/D67/1.041.01.821.03.080.0078795500/D

8 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mmNo.& dia. 
of wires No./mmThickness 
of insulation mmThickness 
of sheath 
mmOverall diameter (Approx.) 
mmMaximum conductor resistance 
(at20C) 
Ohm/kmMinimum insulation resistance 
(at70C) 
Ohm/kmCable 
weight (Approx.) kg/kmStandard Length 
m80.57/0.300.81.813.536.00.0162195500/D0.757/0.370.81.814.024.50.0142230500/D17/0.400.81.814.518.10.0135250500/D1.57/0.500.81.815.512.10.0115310500/D2.57/0.670.81.817.57.410.0093440500/D47/0.851.01.821.04.610.0092660500/D67/1.041.01.823.03.080.0078875500/D

9 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
90.57/0.300.81.814.036.00.0162220500/D0.757/0.370.81.815.024.50.0142265500/D17/0.400.81.815.518.10.0135285500/D1.57/0.500.81.816.512.10.0115355500/D2.57/0.670.81.818.57.410.0093505500/D47/0.851.01.822.54.610.0092760500/D67/1.041.01.824.53.080.00781015500/D

10 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
100.57/0.300.81.815.536.00.0162240500/D0.757/0.370.81.816.024.50.0142285500/D17/0.400.81.816.518.10.0135310500/D1.57/0.500.81.818.012.10.0115385500/D2.57/0.670.81.820.07.410.0093550500/D47/0.851.01.824.54.610.0092825500/D67/1.041.01.827.03.080.00781100500/D

11 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
110.57/0.300.81.815.536.00.0162255500/D0.757/0.370.81.816.524.50.0142315500/D17/0.400.81.817.018.10.0135340500/D1.57/0.500.81.818.512.10.0115425500/D2.57/0.670.81.821.07.410.0093605500/D47/0.851.01.825.04.610.0092915500/D67/1.041.01.827.53.080.00781220500/D

12 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
120.57/0.300.81.815.536.00.0162265500/D0.757/0.370.81.816.524.50.0142320500/D17/0.400.81.817.018.10.0135345500/D1.57/0.500.81.818.512.10.0115440500/D2.57/0.670.81.821.07.410.0093630500/D47/0.851.01.825.04.610.0092950500/D67/1.041.01.827.53.080.00781270500/D


13 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
130.57/0.300.81.816.536.00.0162295500/D0.757/0.370.81.817.524.50.0142355500/D17/0.400.81.818.018.10.0135380500/D1.57/0.500.81.819.512.10.0115485500/D2.57/0.670.81.822.07.410.0093695500/D47/0.851.01.826.54.610.00921050500/D67/1.041.01.829.03.080.00781405500/D


14 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
140.57/0.300.81.816.536.00.0162300500/D0.757/0.370.81.817.524.50.0142360500/D17/0.400.81.818.018.10.0135390500/D1.57/0.500.81.819.512.10.0115495500/D2.57/0.670.81.822.07.410.0093715500/D47/0.851.01.826.54.610.00921085500/D67/1.041.01.829.03.080.00781455500/D


15 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
150.57/0.300.81.817.036.00.0162330500/D0.757/0.370.81.818.524.50.0142395500/D17/0.400.81.819.018.10.0135425500/D1.57/0.500.81.820.512.10.0115545500/D2.57/0.670.81.823.07.410.0093785500/D47/0.851.01.828.04.610.00921195500/D67/1.041.01.831.03.080.00781600500/D


16 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
160.57/0.300.81.817.036.00.0162330500/D0.757/0.370.81.818.524.50.0142400500/D17/0.400.81.819.018.10.0135435500/D1.57/0.500.81.820.512.10.0115555500/D2.57/0.670.81.823.07.410.0093805500/D47/0.851.01.828.04.610.00921230500/D67/1.041.01.831.03.080.00781650500/D


17 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
170.57/0.300.81.818.036.00.0162355500/D0.757/0.370.81.819.024.50.0142430500/D17/0.400.81.819.518.10.0135465500/D1.57/0.500.81.821.512.10.0115595500/D2.57/0.670.81.824.07.410.0093865500/D47/0.851.01.829.54.610.00921315500/D67/1.041.01.932.53.080.00781785500/D


18 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
180.57/0.300.81.818.036.00.0162360500/D0.757/0.370.81.819.024.50.0142435500/D17/0.400.81.819.518.10.0135475500/D1.57/0.500.81.821.512.10.0115605500/D2.57/0.670.81.824.07.410.0093885500/D47/0.851.01.829.54.610.00921350500/D67/1.041.01.932.53.080.00781835500/D

19 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
190.57/0.300.81.818.036.00.0162365500/D0.757/0.370.81.819.024.50.0142445500/D17/0.400.81.819.518.10.0135480500/D1.57/0.500.81.821.512.10.0115620500/D2.57/0.670.81.824.07.410.0093905500/D47/0.851.01.829.54.610.00921385500/D67/1.041.01.932.53.080.00781885500/D

20 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
200.57/0.300.81.819.036.00.0162390500/D0.757/0.370.81.820.024.50.0142475500/D17/0.400.81.820.518.10.0135515500/D1.57/0.500.81.822.512.10.0115665500/D2.57/0.670.81.825.57.410.0093975500/D47/0.851.01.831.04.610.00921490500/D67/1.041.02.034.53.080.00782040500/D

21 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
210.57/0.300.81.819.036.00.0162400500/D0.757/0.370.81.820.024.50.0142490500/D17/0.400.81.820.518.10.0135530500/D1.57/0.500.81.822.512.10.0115685500/D2.57/0.670.81.825.57.410.00931005500/D47/0.851.01.831.04.610.00921540500/D67/1.041.02.034.53.080.00782040500/D

22 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
220.57/0.300.81.820.036.00.0162430500/D0.757/0.370.81.821.024.50.0142520500/D17/0.400.81.821.518.10.0135565500/D1.57/0.500.81.823.512.10.0115730500/D2.57/0.670.81.82657.410.00931070500/D47/0.851.01.932.54.610.00921655500/D67/1.041.02.036.53.080.00782245500/D

23 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
230.57/0.300.81.819.536.00.0162440500/D0.757/0.370.81.821.024.50.0142540500/D17/0.400.81.821.518.10.0135585500/D1.57/0.500.81.823.512.10.0115755500/D2.57/0.670.81.826.57.410.00931105500/D47/0.851.01.932.54.610.00921710500/D67/1.041.02.036.53.080.00782330500/D

24 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
240.57/0.300.81.821.036.00.0162460500/D0.757/0.370.81.822.024.50.0142560500/D17/0.400.81.823.018.10.0135605500/D1.57/0.500.81.824.512.10.0115785500/D2.57/0.670.81.828.07.410.00931150500/D47/0.851.02.034.54.610.00921795500/D67/1.041.02.036.53.080.00782330500/D

25 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
250.57/0.300.81.821.036.00.0162490500/D0.757/0.370.81.822.524.50.0142595500/D17/0.400.81.823.018.10.0135645500/D1.57/0.500.81.825.512.10.0115835500/D2.57/0.670.81.828.57.410.00931225500/D47/0.851.02.035.54.610.00921915500/D67/1.041.02.139.53.080.00782595500/D

26 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
270.57/0.300.81.821.036.00.0162500500/D0.757/0.370.81.822.524.50.0142610500/D17/0.400.81.823.018.10.0135665500/D1.57/0.500.81.825.512.10.0115860500/D2.57/0.670.81.828.57.410.00931270500/D47/0.851.02.035.54.610.00921985500/D67/1.041.02.139.53.080.00782700500/D

27 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mmNo.& dia. 
of wires No./mmThickness 
of insulation mmThickness 
of sheath 
mmOverall diameter (Approx.) 
mmMaximum conductor resistance 
(at20C) 
Ohm/kmMinimum insulation resistance 
(at70C) 
Ohm/kmCable 
weight (Approx.) kg/kmStandard Length 
m270.57/0.300.81.821.036.00.0162500500/D0.757/0.370.81.822.524.50.0142610500/D17/0.400.81.823.018.10.0135665500/D1.57/0.500.81.825.512.10.0115860500/D2.57/0.670.81.828.57.410.00931270500/D47/0.851.02.035.54.610.00921985500/D67/1.041.02.139.53.080.00782700500/D

28 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
280.57/0.300.81.822.036.00.0162535500/D0.757/0.370.81.823.524.50.0142650500/D17/0.400.81.824.018.10.0135710500/D1.57/0.500.81.826.012.10.0115915500/D2.57/0.670.81.830.07.410.00931350500/D47/0.851.02.037.04.610.00922110500/D67/1.041.02.241.53.080.00782885500/D

29 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
290.57/0.300.81.822.036.00.0162540500/D0.757/0.370.81.823.524.50.0142660500/D17/0.400.81.824.018.10.0135715500/D1.57/0.500.81.826.012.10.0115930500/D2.57/0.670.81.830.07.410.00931370500/D47/0.851.02.037.04.610.00922145500/D67/1.041.02.241.53.080.00782940500/D

30 Core CVV Control Cable

No. of coreNominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness 
of insulation mm
Thickness 
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
300.57/0.300.81.822.036.00.0162540500/D0.757/0.370.81.823.024.50.0142665500/D17/0.400.81.824.018.10.0135725500/D1.57/0.500.81.826.012.10.0115940500/D2.57/0.670.81.830.07.410.00931395500/D47/0.851.02.037.04.610.00922180500/D67/1.041.02.241.53.080.00782990500/D

The table of 0.6/1 KV CVV shown concentric stranded conductor only. If you want to have solid or flexible conductor type, please contact with our Sales Department.

Packing & Shipping
We provide you with the best product packaging design services, thereby allowing you to save more shipping charges.

0.6/1kv IEC 60502 2-30 Core Cu/PVC/PVC Flame Retardant Control Cable Cvv

FAQ

1. Q: Are you the factory or the trading company?
    A: We are the factory. 
2. Q: How long is your guarantee Period?
    A: We usually offer 1 year guarantee for our general products.
3. Q: How can I get the samples?
    A: We can make the sample order. And usually you will charge for it. 
    But the samples fee will be return to you when you make the bulk order.
4. Q: Where is your factory? How can we visit your factory?
    A: Our factory located in Jiaozuo city, Henan Province and our office is in Zhengzhou city. You could reach here by train and by air. We can pick you up in the airport and the railway station.
5. Q: What is your MOQ?
    A: It`s base on the cable type or size. Please contact Ms. Melon. She will offer you the details.

Factory

Established in 2004, Henan Hongda Cable Co., Ltd, is dedicated into manufacturing various types of electric power wire and cable. Today, Henan Hongda has grown into an integrated system solution provider in electric power distribution industry, extending the business from power cable and electric wire manufacture to electric power distribution system design, and electric distribution system construction and installation.
Today, Henan Hongda has grown into an integrated system solution provider in electric power distribution industry, extending the business from power cable and electric wire manufacture to electric power distribution system design, and electric distribution system construction and installation.

Our Service

1. Design wire and cable according to your real application
2. Optimized reel size for freight cost saving
3. Customized package to feature your brand
4. Short lead time to meet your urgent demand
5. Diversified delivery terms for your options
6. Quick response (24 hours on line)
7. Professional knowledge for clear answer to your any question
8. Comprehensive technical documents to support your tender bidding
9. One-year limited warranty for our wire and cable
10. Cable sample available
11. Specify the cable only according to the location
12. OEM is available
13. Abundant cables and wires for your option

Contact Us

0.6/1kv IEC 60502 2-30 Core Cu/PVC/PVC Flame Retardant Control Cable Cvv
************************************************************************************************