Duplex (1+1) Service Drop Alu Conductor ABC Cable
YIFANG ELECTRIC GROUP INC.- Type:Insulated
- Conductor Type:Stranded
- Application:Overhead
- Conductor Material:Aluminum
- Sheath Material:None
- Insulation Material:PVC or XLPE or PE
Base Info
- Model NO.:ABC cable
- Material Shape:Round Wire
- Range of Application:Overhead
- Certification:ISO9001, CCC
- Brand:Yifang Cable
- Product Name:Duplex Service Drop Aluminum Conductor Cable
- Transport Package:Drums or Reels
- Specification:IEC, DIN, BS, GOST, ANSI. etc
- Trademark:Yifang cable
- Origin:China
- HS Code:8544492100
- Production Capacity:50, 000 Kilometers Per Month
Description
Basic Info.
Model NO. ABC cable Material Shape Round Wire Range of Application Overhead Certification ISO9001, CCC Brand Yifang Cable Product Name Duplex Service Drop Aluminum Conductor Cable Transport Package Drums or Reels Specification IEC, DIN, BS, GOST, ANSI. etc Trademark Yifang cable Origin China HS Code 8544492100 Production Capacity 50, 000 Kilometers Per MonthProduct Description
Duplex Service Drop AAC-Aluminum ConductorDuplex Service Drop ACSR Neutral-Messenger Aluminum Conductor
Duplex Service Drop AAAC 6201 Alloy Neutral Messenger Aluminum Conductor
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum Conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

Item # | Phase conductor size AWG | Phase conductor stranding | Phase conductor Insulation Thickness | Bare Neutral Messenger Size AWG | Bare Neutral Messenger Stranding | Bare Neutral Messenger breaking strength | Weight Per 1000ft-XLP | Weight Per 1000ft-Poly | Ampacity -XLP | Ampacity -Poly |
Pekingese | 6 | Solid | 45 mls | 6 | 7/w | 563 Lbs | 63.5 Lbs | 61.7 Lbs | 70 Amps | 70 Amps |
Collie | 6 | 7/w | 45 mls | 6 | 7/w | 563 Lbs | 66.8 Lbs | 63.1 Lbs | 70 Amps | 70 Amps |
Dachshund | 4 | Solid | 45 mls | 4 | 7/w | 881 Lbs | 95.5 Lbs | 93.4 Lbs | 90 Amps | 90 Amps |
Spaniel | 4 | 7/w | 45 mls | 4 | 7/w | 881 Lbs | 100.5 Lbs | 95.4 Lbs | 90 Amps | 90 Amps |
Doberman | 2 | 7/w | 45 mls | 2 | 7/w | 1350 Lbs | 152.7 Lbs | 145.7 Lbs | 120 Amps | 120 Amps |
Malemute | 1/0 | 19/w | 60 mls | 1/0 | 7/w | 1990 Lbs | 242.6 Lbs | 234.2 Lbs | 160 Amps | 160 Amps |
Setter | 6 | Solid | 45 mls | 6 | 6/1 | 1190 Lbs | 75.0 Lbs | 73.2 Lbs | 70 Amps | 70 Amps |
Shepherd | 6 | 7/w | 45 mls | 6 | 6/1 | 1190 Lbs | 78.3 Lbs | 74.6 Lbs | 70 Amps | 70 Amps |
Eskimo | 4 | Solid | 45 mls | 4 | 6/1 | 1860 Lbs | 113.7 Lbs | 111.6 Lbs | 90 Amps | 90 Amps |
Terrier | 4 | 7/w | 45 mls | 4 | 6/1 | 1860 Lbs | 118.7 Lbs | 113.6 Lbs | 90 Amps | 90 Amps |
Chow | 2 | 7/w | 45 mls | 2 | 6/1 | 2850 Lbs | 181.7 Lbs | 174.7 Lbs | 120 Amps | 120 Amps |
Bull | 1/0 | 19/w | 60 mls | 1/0 | 6/1 | 4380 Lbs | 288.7 Lbs | 280.3 Lbs | 160 Amps | 160 Amps |
Chihuahua | 6 | Solid | 45 mls | 6 | 7 | 1110 Lbs | 67.6 Lbs | 65.8 Lbs | 70 Amps | 70 Amps |
Vizsla | 6 | 7/w | 45 mls | 6 | 7 | 1110 Lbs | 70.9 Lbs | 67.2 Lbs | 70 Amps | 70 Amps |
Harrier | 4 | Solid | 45 mls | 4 | 7 | 1760 Lbs | 102.0 Lbs | 99.9 Lbs | 90 Amps | 90 Amps |
Whippet | 4 | 7/w | 45 mls | 4 | 7 | 1760 Lbs | 107.0 Lbs | 101.9 Lbs | 90 Amps | 90 Amps |
Schnauzer | 2 | 7/w | 45 mls | 2 | 7 | 2800 Lbs | 163.3 Lbs | 156.2 Lbs | 120 Amps | 120 Amps |
Heeler | 1/0 | 19/w | 60 mls | 1/0 | 7 | 4460 Lbs | 259.2 Lbs | 250.8 Lbs | 160 Amps | 160 Amps |