H05gg-F Electric Cable for Storage Heater Copper Conductor Rubber Insulation Flexible Electric Wire
Tianjin Feiya Electric Wire & Cable Co., Ltd.- Type:Insulated
- Conductor Type:Stranded
- Application:Overhead, Underground
- Conductor Material:Copper
- Sheath Material:Rubber
- Insulation Material:Rubber
Base Info
- Model NO.:H05gg-F
- Material Shape:Round Wire
- Range of Application:Flame Retardant
- Certification:ISO9001, CE, UL, CCC, RoHS, VDE
- Brand:Feiya
- Color:Black Red Yellow, According to Voltage Level
- Whether It Is Environmentally Friendly:Yes
- Whether Quality Inspection:Provide Inspection Certificate
- Standard:Customized According to Specified National Standar
- OEM/ODM:Accepted
- Core:Single Core and Multicore
- Transport Package:Standard Export Packaging
- Specification:International General Specifications
- Trademark:Fengda
- Origin:Tianjin, China(Mainland)
- HS Code:8544492100
- Production Capacity:100000,Day
Description
Use in domestic premises, kitchens and offices, for ordinary duty applications and supplying appliances where cables are subject to low mechanical stresses (e.g. vacuum cleaners, cooking appliances, soldering irons, toasters, domestic portable tools, hand held inspection lamps) use outdoors for temporary periods of short duration.
Technical Data:
Review number | n. 5 - 22/4/2015 |
Nominal tension | 300/500 V |
Type of insulation | EI3 |
Type of outer sheath | EM4 |
Color of the outer sheath | Black |
Operating temperature | -5° C | +110° C |
Short circuit temperature | 250° C on the conductor (max 5 sec.) |
Test voltage | 2000 V |
Cable marking | H05GG-F |
Minimum radius of curvature | For cables with diameter up to 12 mm 4 times the max outer diameter in mobile laying and 3 times in fixed laying. For cables with diameter greater than 12 mm 5 times the max outer diameter in mobile laying and 4 times in fixed laying. |
Insulation tolerance | ± 0,1 |
Sheath tolerance | ± 0,2 |
Type of the cables
Nominal section | Max wire diameter | Conductor diameter | Insulation thickness | Average sheath thickness | Minimum external diameter | Maximum external diameter | Copper electric resistance 20°C | Indicative weight | CU Factor |
(Nxmm2) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (Ω/km) | (kg/km) | (kg/km) |
2x0,75 | 0,21 | 1,052 | 0,60 | 0,80 | 5,7 | 7,4 | 26,00 | 58 | 14,4 |
2x1,00 | 0,21 | 1,215 | 0,60 | 0,90 | 6,1 | 8,0 | 19,50 | 69 | 19,2 |
2x1,50 | 0,26 | 1,435 | 0,80 | 1,00 | 7,6 | 9,8 | 13,30 | 100 | 28,8 |
2x2,50 | 0,26 | 1,879 | 0,90 | 1,10 | 9,0 | 11,6 | 7,98 | 145 | 48 |
3x0,75 | 0,21 | 1,052 | 0,60 | 0,90 | 6,2 | 8,1 | 26,00 | 72 | 21,6 |
3x1,00 | 0,21 | 1,215 | 0,60 | 0,90 | 6,5 | 8,5 | 19,50 | 83 | 28,8 |
3x1,50 | 0,26 | 1,435 | 0,80 | 1,00 | 8,0 | 10,4 | 13,30 | 125 | 43,2 |
3x2,50 | 0,26 | 1,879 | 0,90 | 1,10 | 9,6 | 12,4 | 7,98 | 175 | 72 |
3x4,00 | 0,31 | 2,445 | 1,00 | 1,20 | 11,3 | 14,5 | 4,95 | 217 | 115,2 |
3x6,00 | 0,31 | 2,955 | 1,00 | 1,40 | 12,8 | 16,3 | 3,30 | 283 | 172,8 |
4x0,75 | 0,21 | 1,052 | 0,60 | 0,90 | 6,8 | 8,8 | 26,00 | 90 | 28,8 |
4x1,00 | 0,21 | 1,215 | 0,60 | 0,90 | 7,1 | 9,3 | 19,50 | 100 | 38,4 |
4x1,50 | 0,26 | 1,435 | 0,80 | 1,10 | 9,0 | 11,6 | 13,30 | 150 | 57,6 |
4x2,50 | 0,26 | 1,879 | 0,90 | 1,20 | 10,7 | 13,8 | 7,98 | 220 | 96 |
4x4,00 | 0,31 | 2,445 | 1,00 | 1,30 | 12,7 | 16,2 | 4,95 | 271 | 153,6 |
4x6,00 | 0,31 | 2,955 | 1,00 | 1,50 | 14,2 | 18,1 | 3,30 | 375 | 230,4 |
5x0,75 | 0,21 | 1,052 | 0,60 | 1,00 | 7,6 | 9,9 | 26,00 | 105 | 36 |
5x1,00 | 0,21 | 1,215 | 0,60 | 1,00 | 8,0 | 10,3 | 19,50 | 120 | 48 |
5x1,50 | 0,26 | 1,435 | 0,80 | 1,10 | 9,8 | 12,7 | 13,30 | 180 | 72 |
5x2,50 | 0,26 | 1,879 | 0,90 | 1,30 | 11,9 | 15,3 | 7,98 | 260 | 120 |