- Model NO.:Control Cable
- Material Shape:Round Wire
- Range of Application:Flame Retardant
- Certification:ISO9001, CE, CCC
- Brand:OEM
- Transport Package:Wooden Drum
- Specification:1.5mm to 50mm2
- Trademark:OEM
- Origin:China(Mainland)
- HS Code:8544492100
- Production Capacity:50 Kilometer,Month
No. of core | Nominal cross- sectional area sq.mm | No.& dia. of wires No./mm | Thickness of insulation mm | Thickness of sheath mm | Overall diameter (Approx.) mm | Maximum conductor resistance (at20C) Ohm/km | Minimum insulation resistance (at70C) Ohm/km | Cable weight (Approx.) kg/km | Standard Length m |
3 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 110 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 10.5 | 24.5 | 0.0142 | 125 | 500/D |
1 | 7/0.40 | 0.8 | 1.8 | 11.0 | 18.1 | 0.0135 | 135 | 500/D |
1.5 | 7/0.50 | 0.8 | 1.8 | 11.5 | 12.1 | 0.0115 | 160 | 500/D |
2.5 | 7/0.67 | 0.8 | 1.8 | 13.0 | 7.41 | 0.0093 | 220 | 500/D |
4 | 7/0.85 | 1.0 | 1.8 | 15.0 | 4.61 | 0.0092 | 315 | 500/D |
6 | 7/1.04 | 1.0 | 1.8 | 16.5 | 3.08 | 0.0078 | 405 | 500/D |
4 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm | No.& dia. of wires No./mm | Thickness of insulation mm | Thickness of sheath mm | Overall diameter (Approx.) mm | Maximum conductor resistance (at20C) Ohm/km | Minimum insulation resistance (at70C) Ohm/km | Cable weight (Approx.) kg/km | Standard Length m |
4 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.0 | 36.0 | 0.0162 | 130 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 11.5 | 24.5 | 0.0142 | 150 | 500/D |
1 | 7/0.40 | 0.8 | 1.8 | 11.5 | 18.1 | 0.0135 | 160 | 500/D |
1.5 | 7/0.50 | 0.8 | 1.8 | 12.5 | 12.1 | 0.0115 | 195 | 500/D |
2.5 | 7/0.67 | 0.8 | 1.8 | 14.0 | 7.41 | 0.0093 | 265 | 500/D |
4 | 7/0.85 | 1.0 | 1.8 | 16.5 | 4.61 | 0.0092 | 390 | 500/D |
6 | 7/1.04 | 1.0 | 1.8 | 17.0 | 3.08 | 0.0078 | 510 | 500/D |
5 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm | No.& dia. of wires No./mm | Thickness of insulation mm | Thickness of sheath mm | Overall diameter (Approx.) mm | Maximum conductor resistance (at20C) Ohm/km | Minimum insulation resistance (at70C) Ohm/km | Cable weight (Approx.) kg/km | Standard Length m |
5 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.5 | 36.0 | 0.0162 | 150 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 12.5 | 24.5 | 0.0142 | 175 | 500/D |
1 | 7/0.40 | 0.8 | 1.8 | 12.5 | 18.1 | 0.0135 | 190 | 500/D |
1.5 | 7/0.50 | 0.8 | 1.8 | 13.5 | 12.1 | 0.0115 | 230 | 500/D |
2.5 | 7/0.67 | 0.8 | 1.8 | 15.0 | 7.41 | 0.0093 | 320 | 500/D |
4 | 7/0.85 | 1.0 | 1.8 | 18.0 | 4.61 | 0.0092 | 470 | 500/D |
6 | 7/1.04 | 1.0 | 1.8 | 19.5 | 3.08 | 0.0078 | 620 | 500/D |
6 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm | No.& dia. of wires No./mm | Thickness of insulation mm | Thickness of sheath mm | Overall diameter (Approx.) mm | Maximum conductor resistance (at20C) Ohm/km | Minimum insulation resistance (at70C) Ohm/km | Cable weight (Approx.) kg/km | Standard Length m |
6 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 165 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 190 | 500/D |
1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 205 | 500/D |
1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 255 | 500/D |
2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 355 | 500/D |
4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 525 | 500/D |
6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 690 | 500/D |
7 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm | No.& dia. of wires No./mm | Thickness of insulation mm | Thickness of sheath mm | Overall diameter (Approx.) mm | Maximum conductor resistance (at20C) Ohm/km | Minimum insulation resistance (at70C) Ohm/km | Cable weight (Approx.) kg/km | Standard Length m |
7 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 170 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 200 | 500/D |
1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 215 | 500/D |
1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 270 | 500/D |
2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 380 | 500/D |
4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 570 | 500/D |
6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 795 | 500/D |
8 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm | No.& dia. of wires No./mm | Thickness of insulation mm | Thickness of sheath mm | Overall diameter (Approx.) mm | Maximum conductor resistance (at20C) Ohm/km | Minimum insulation resistance (at70C) Ohm/km | Cable weight (Approx.) kg/km | Standard Length m |
8 | 0.5 | 7/0.30 | 0.8 | 1.8 | 13.5 | 36.0 | 0.0162 | 195 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 14.0 | 24.5 | 0.0142 | 230 | 500/D |
1 | 7/0.40 | 0.8 | 1.8 | 14.5 | 18.1 | 0.0135 | 250 | 500/D |
1.5 | 7/0.50 | 0.8 | 1.8 | 15.5 | 12.1 | 0.0115 | 310 | 500/D |
2.5 | 7/0.67 | 0.8 | 1.8 | 17.5 | 7.41 | 0.0093 | 440 | 500/D |
4 | 7/0.85 | 1.0 | 1.8 | 21.0 | 4.61 | 0.0092 | 660 | 500/D |
6 | 7/1.04 | 1.0 | 1.8 | 23.0 | 3.08 | 0.0078 | 875 | 500/D |
9 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm | No.& dia. of wires No./mm | Thickness of insulation mm | Thickness of sheath mm | Overall diameter (Approx.) mm | Maximum conductor resistance (at20C) Ohm/km | Minimum insulation resistance (at70C) Ohm/km | Cable weight (Approx.) kg/km | Standard Length m |
9 | 0.5 | 7/0.30 | 0.8 | 1.8 | 14.0 | 36.0 | 0.0162 | 220 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 15.0 | 24.5 | 0.0142 | 265 | 500/D |
1 | 7/0.40 | 0.8 | 1.8 | 15.5 | 18.1 | 0.0135 | 285 | 500/D |
1.5 | 7/0.50 | 0.8 | 1.8 | 16.5 | 12.1 | 0.0115 | 355 | 500/D |
2.5 | 7/0.67 | 0.8 | 1.8 | 18.5 | 7.41 | 0.0093 | 505 | 500/D |
4 | 7/0.85 | 1.0 | 1.8 | 22.5 | 4.61 | 0.0092 | 760 | 500/D |
6 | 7/1.04 | 1.0 | 1.8 | 24.5 | 3.08 | 0.0078 | 1015 | 500/D |
10 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm | No.& dia. of wires No./mm | Thickness of insulation mm | Thickness of sheath mm | Overall diameter (Approx.) mm | Maximum conductor resistance (at20C) Ohm/km | Minimum insulation resistance (at70C) Ohm/km | Cable weight (Approx.) kg/km | Standard Length m |
10 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 240 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.0 | 24.5 | 0.0142 | 285 | 500/D |
1 | 7/0.40 | 0.8 | 1.8 | 16.5 | 18.1 | 0.0135 | 310 | 500/D |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.0 | 12.1 | 0.0115 | 385 | 500/D |
2.5 | 7/0.67 | 0.8 | 1.8 | 20.0 | 7.41 | 0.0093 | 550 | 500/D |
4 | 7/0.85 | 1.0 | 1.8 | 24.5 | 4.61 | 0.0092 | 825 | 500/D |
6 | 7/1.04 | 1.0 | 1.8 | 27.0 | 3.08 | 0.0078 | 1100 | 500/D |
Packing shipping


Why Choose Us ?
1. We have a large production base, and advanced production equipment
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas

Any problem and inquiry pls contact with Tina
Phone number: +86-15737156317