UL1571 Low Voltage Electrical Copper Wire
Maximum Resistance at 20 ºCΩ/kmAWGNo./mmDia.mmNom. Thick.mmNom.Dia.mm367/0.0500.150.150.451490347/0.0650.1950.150.5908327/0.080.240.230.70597307/0.10.300.300.90354307/0.10.300.200.70354287/0.1270.380.260.90223287/0.1270.380.260.90223267/0.160.480.261.00139247/0.20.60.251.1088.9227/0.160.7
-
1.5mm 2.5mm Copper Conductor PVC Insulated Electric Wire Cable
AWGNO.of CondInsulation Thick.Outside Thick.Packingmmmmmmm/rΩ/mm307/0.10.791.90610354.33287/0.1270.792.00610223.75267/0.160.792.05610139.762411/0.160.792.2061088.362217/0.160.792.4061060.162021/0.1780.792.5561038.581834/0.1780.792.7561022.981626/0.2540.793.1030515.061441/0.2540.793.503059.6512
-
UL1032 18AWG Stranded Tinned Copper Electronic Wire Single Conductor Electrical Cable
Rated Temperature90ºCInsulatedPVC insulationStandardMaximum Resistance at 20ºCΩ/kmAWGNo./mmDia.mmNom. Thick.mmNom.Dia.mm267/0.160.480.802.081392411/0.160.610.802.2088.92217/0.160.760.802.3657.52026/0.160.940.802.5434.61841/0.161.180.802.7823.31626/0.2541.490.803.1015.11441/0.2541.870
-
UL Certified UL1672 PVC Double Insulated Stranded Bare Copper Wire for Building Cable
AWGNO.of CondInsulation Thick.Outside Thick.Packingmmmmmmm/rΩ/mm287/0.1270.450.45610.00223.75267/0.160.450.45610.00139.762411/0.160.450.45610.0088.362217/0.160.450.45610.0060.162021/0.1780.450.45610.0038.581834/0.1780.450.45610.0022.981626/0.2540.450.45610.0015.061441/0.2540.450.45610.009.6512
-
Us Certified Stranded UL1032 Tinned Copper Single Wire for Toy Wire
Maximum Resistance at 20ºCΩ/kmAWGNo./mmDia.mmNom. Thick.mmNom.Dia.mm267/0.160.480.802.081392411/0.160.610.802.2088.92217/0.160.760.802.3657.52026/0.160.940.802.5434.61841/0.161.180.802.7823.31626/0.2541.490.803.1015.11441/0.2541.870.903.709.21265/0.2542.361.024.405.41065/0.322.971.025.004
-
350 MHz UTP Cat5e Outdoor, with ETL /CPR Eca Cable
Insulation colorsBlue-White/Blue,Orange-White/OrangeGreen-White/Green,Brown-White/BrownRip CordCottonOut Jacket5.1±0.2mm PVC (PE or LSZH)Messenger1.3mm Steel9.5 Ohms/100mResistance 20ºCRes. unbalance (%)Max. 2.5Pair to Ground330 pF/100mCapacitance UnbalanceTransfer ImpendanceMax 10 mOhms
-
UL1213 PTFE 18AWG Insulated Wire Cable 600V 105c Rated Temperature Cable
Maximum Resistance at 20 ºCΩ/kmAWGNo./mmDia.mmNom. Thick.mmNom. Dia.mm267/0.160.480.491.46139
-
10 ga 500 ft. Blue Tracer Wire Potable Water Lines
ApplicationWe design Cu (copper) tracer wire for 30-600 Volts applications. It could be used to locate underground utility lines such as gas, water, sewer, telecommunication pipes and cables. In conclusion, we can use it in open cut projects.SpecificationIt is consist of a copper conductor and of 8-