Cable & Wire

Thermocouple, Surface Thermocouple

Shanghai Total Industrial Co., Ltd.
  • Trademark:TOTAL

Base Info

    Description

    Model Number
     
    Temperature Range
     
    Size
     
    Hot response time
     
    Application
     
    TP-01K
     
    -50~204 o C
     
     
     
    < 5 seconds
     
    Suitable for quickly measuring of air and gas, not suitable for liquid measuring.
     
    TP-01
     
    -50~204 o C
     
     
     
    < 5 seconds
     
    Suitable for quickly measuring of air and gas, not suitable for liquid measuring.
     
    TP-01A
     
    -50~204 o C
     
     
     
    < 5 seconds
     
    Suitable for quickly measuring of air and gas, not suitable for liquid measuring.
     
    TP-01B
     
    -50~204 o C
     
    19mm plug
     
    < 5 seconds
     
    Suitable for quickly measuring of air and gas, not suitable for liquid measuring.
     
    TP-01C
     
    -50~204 o C
     
    12mm plug
     
    < 5 seconds
     
    Suitable for quickly measuring of air and gas, not suitable for liquid measuring.
     
    Model Number
     
    Temperature Range
     
    Size
     
    Hot response time
     
    Application
     
    TP-02 (spring wire)
     
    -50~400 o C
     
    3mm*8cm
     
    < 15 seconds
     
    Suitable for measuring the temperature of liquid and gel.
     
    TP-02 (straight wire)
     
    -50~400 o C 
     
    3mm*8cm
     
    < 15 seconds
     
    Suitable for measuring the temperature of liquid and gel.
     
    TP-02A (spring wire)
     
    -50~400 o C 
     
    3mm*8cm
     
    < 15 seconds
     
    Suitable for measuring the temperature of liquid and gel.
     
    TP-02A (straight wire)
     
    -50~400 o C 
     
    3mm*8cm
     
    < 15 seconds
     
    Suitable for measuring the temperature of liquid and gel.
     
    TP-02B (spring wire)
     
    -50~400 o C 
     
    3mm*8cm
     
    < 15 seconds
     
    Suitable for measuring the temperature of liquid and gel.
     
    TP-02B (straight wire)
     
    -50~400 o C
     
    3mm*8cm
     
    < 15 seconds
     
    Suitable for measuring the temperature of liquid and gel.
     
    Model Number
     
    The limited temperature
     
    Size
     
    Hot response time
     
    Application
     
    WRNM-104
     
    800 o C
     
    dia3mm*30CM
     
    10 seconds
     
    Suitable for measuring the inner temperature within the flowings, such as liquid and vapour etc.
     
    WRNM-104
     
    800 o C
     
    dia4mm*30CM
     
    10 seconds
     
    WRNM-104
     
    800 o C
     
    dia5mm*30CM
     
    10 seconds
     
    WRNM-104
     
    800 o C 
     
    dia6mm*30CM
     
    10 seconds
     
    WRNM-104
     
    800 o C 
     
    dia3mm*50CM
     
    10 seconds
     
    WRNM-104 / TP-03
     
    800 o C 
     
    dia4mm*50CM
     
    10 seconds
     
    WRNM-104
     
    800 o C
     
    dia5mm*50CM
     
    10 seconds
     
    WRNM-104 / TP-04
     
    800 o C
     
    dia6mm*50CM
     
    10 seconds
     
    WRNM-104
     
    800 o C
     
    dia3mm*100CM
     
    10 seconds
     
    WRNM-104
     
    800 o C
     
    dia4mm*100CM
     
    10 seconds
     
    WRNM-104
     
    800 o C
     
    dia5mm*100CM
     
    10 seconds
     
    WRNM-104
     
    800 o C 
     
    dia6mm*100CM
     
    10 seconds
     
    WRNM-104
     
    800 o C 
     
    dia3mm*150CM
     
    10 seconds
     
    WRNM-104
     
    800 o C 
     
    dia4mm*150CM
     
    10 seconds
     
    WRNM-104
     
    800 o C
     
    dia5mm*150CM
     
    10 seconds
     
    WRNM-104
     
    800 o C
     
    dia6mm*150CM
     
    10 seconds
     
    WRNM-104
     
    800 o C 
     
    dia3mm*200CM
     
    10 seconds
     
    WRNM-104
     
    800 o C 
     
    dia4mm*200CM
     
    10 seconds
     
    WRNM-104
     
    800 o C 
     
    dia5mm*200CM
     
    10 seconds
     
    WRNM-104
     
    800 o C
     
    dia6mm*200CM
     
    10 seconds
     
    Model Number
     
    The limited temperature
     
    Size
     
    Hot response time
     
    Application
     
    WRNM-101
     
    250 o C
     
     
     
    < 5 seconds
     
    Suitable for measuring the temperature with smooth metal, plastic cylinder or roll’s outside surface which is more than 130mm.
     
    WRNM-106
     
    500 o C
     
    dia3mm (dia4, 5, 6mm is available)
     
    10 seconds
     
    Suitable for measuring semi-solid flowing material, plastic, clay and so on, and it also can be used in food industry.
     
    WRNM-108
     
    700 o C
     
     
     
    < 10 seconds
     
    Suitable for measuring the inner temperature within the flowing gas and vapour