Multi Conductor Shield Electric Wire UL2851 with PVC Insulated for Connection of Motor Windings
Rated Temperature80ºCConductorStranded, tinned or bare copper conductor, 40 AWG minimumStandardUL Subject 758, UL1581 & CSA C22.2 No.210.2ApplicationFor internal wiring of electronic equipment in Class 2 systemsMaximum Resistance at 20ºCΩ/kmAWGNo./mmDia.mmNom. Thick.mmNom.Dia.mmN
-
AWG Easy Cutting PVC Electronic Awm UL1015 Electric Wire Cable
AWGNO.of CondInsulation Thick.Outside Thick.Packingmmmmmmm/rΩ/mm307/0.10.791.90610354.33287/0.1270.792.00610223.75267/0.160.792.05610139.762411/0.160.792.2061088.362217/0.160.792.4061060.162021/0.1780.792.5561038.581834/0.1780.792.7561022.981626/0.2540.793.1030515.061441/0.2540.793.503059.6512
-
UL Approved Awm 2725 Shield Multi Core Electric Wires Cables
Maximum Resistance at 20ºCΩ/kmAWGNo./mmDia.mmNom. Thick.mmNom.Dia.mmNo./mmMaterialSpiralNo./mmBraidNo./No./mmNom. Thick.mmNom.Dia.mm2307/0.10.300.250.80--45/0.10.502.7035422819/0.080.400.150.70---0.402.202204307/0.10.300.250.80--59/0.10.392.903544267/0.160.480.261.00-AL16/5/0.120.875.0013
-
UL1332 High Temperature 200 Degree C 300V Tin Plated FEP Electric Wire Cable
Overall Diameter(mm)Nom.Min.Nom.Tol.1037/0.423.542.940.350.303.64±0.151237/0.3745.642.620.350.303.32±0.151419/0.3618.961.850.350.302.60±0.10141/1.1638.961.630.350.302.33±0.101619/0.28714.601.500.330.302.16±0.101626/0.25114.601.500.330.302.14±0.101819/0.23523
-
UL1332 FEP 300V 200 Degree Coated Tinned High Temperature Wire Electrical Wire Cable
Overall Diameter(mm)Nom.Min.Nom.Tol.1037/0.423.542.940.350.303.64±0.151237/0.3745.642.620.350.303.32±0.151419/0.3618.961.850.350.302.60±0.10141/1.1638.961.630.350.302.33±0.101619/0.28714.601.500.330.302.16±0.101626/0.25114.601.500.330.302.14±0.101819/0.23523
-
UL1185 Stranded Tinned Copper PVC Insulated Cable
Rated Temperature80ºCConductorSolid or stranded,tinned or bare copper conductor StandardUL Subject758,UL1581,C22.2ApplicationNO.of Cond/mmInsulated Thick.Braid ShieldJacket Thick.Outside Thick.mmNo./dmmmm307/0.10.4132/0.100.402.10287/0.1270.4134/0.100.402.20267/0.160.4137/0.100.402.302411/0.1
-
Flry-a Bare Copper Car Automotive Wire Electric Wire Cable
Maximum Resistance at 20ºCCross Sectional AreaNO.of CondInsulation Thick.Outside Thick.Weightmm2No./mmmmmmkg/kmΩ/mm0.227/0.210.31.203.5284.800.357/0.260.31.304.7952.000.519/0.190.31.607.0737.210.7519/0.230.31.9010.1924.70119/0.260.42.1012.7918.501.519/0.320.42.4018.3112.70
-
Popular UL3139 Silicone Rubber Insulated High Temperature Flexible Cable
Rated Temperature200ºCConductorSolid or stranded,tinned or bare copper conductorStandardUL Subject758,UL1581,C22.2ApplicationOverall Diameter(mm)Nom.Min.Nom.Tol.1265/0.2545.642.361.151.024.66±0.151441/0.2548.961.91.151.024.20±0.15167/0.4914.601.501.151.023.80±0.15187/0.3923