3X1.0mm2 Fire Alarm Cable
Cable construction :Conductor:Solid Bare Copper 3×1.13mmInsulation:Type:PVC-FPLRDia.over Dielectric: 0.086''nom.(2.2mm)Insulation Color:Blu/BrnSeparator :PET FoilDrain Wire:0.8mm Aluminum/TCCAShield:Aluminum PET (100% Coverage 20% overlapping)Jacket:PVC-FPLRDia.over Jacket: 0.252''(6.4mm)Alarm
-
SAT703 Coaxial Cable
5) Min.Structural Return Loss (5-3000MHz) : 20 dB6) Max. Attenuation :@Frequency (MHz)dB/100 ft (MAX.)dB/100 meters(MAX)5 MHz0.58 dB1.90 dB55 MHz1.60 dB5.25 dB211 MHz1.95 dB10.00 dB250 MHz2.85 dB10.82 dB270 MHz3.05 dB11.04 dB300 MHz3.30 dB11.64 dB330 MHz3.55 dB12.26 dB350 MHz3.85 dB12.63 dB400 MHz4.
-
Rg6u Coax Cable
5) Min.Structural Return Loss (5-3000MHz) : 20 dB6) Max. Attenuation :@Frequency (MHz)dB/100 ft (MAX.)dB/100 meters(MAX)5 MHz0.58 dB1.90 dB55 MHz1.60 dB5.25 dB211 MHz1.95 dB10.00 dB250 MHz2.85 dB10.82 dB270 MHz3.05 dB11.04 dB300 MHz3.30 dB11.64 dB330 MHz3.55 dB12.26 dB350 MHz3.85 dB12.63 dB400 MHz4.
-
AAC Bare Conductor 19/1.80 mm conductor IEC 61089 for Distribution Line
kNDC.20°CΩ/km1071.3510.024.0527.41.952.86331671.7116.085.1243.83.041.78962572.1324.946.4068.44.501.14534072.7040.088.09109.46.800.71586373.3963.1810.20172.310.390.4545100192.59100.1012.90274.817.000.2877125192.89124.6314.50343.621.250.2302160193.27159.5716.40439.826.400.1798200193.66199.90
-
AAC Bare Conductor 19/2.16 mm conductor IEC 61089 for Distribution Line
kNDC.20°CΩ/km1071.3510.024.0527.41.952.86331671.7116.085.1243.83.041.78962572.1324.946.4068.44.501.14534072.7040.088.09109.46.800.71586373.3963.1810.20172.310.390.4545100192.59100.1012.90274.817.000.2877125192.89124.6314.50343.621.250.2302160193.27159.5716.40439.826.400.1798200193.66199.90
-
BCC Conductor Bare Copper Wire Stranded 120mm2 19/2.80 for Earthing system
Nominal CrossSectional AreaConductor constructionApprox. overall diameterApprox. overall weightCurrent CapacityMinimum breaking loadmm²No. x Ø ( mm )mmKg / kmAKN107 x 1.354.190904.02167 x 1.705.11431256.38257 x 2.106.32181609.72357 x 2.507.531020013.77507 x 3.009.044625019.845019 x 1.809
-
0.6/1kV 3X70+1X54,6mm2 Twisted ABC Aerial Bundled Overhead Cable NF C 33-209
Tensile strength not less than90 N/mm2Resistivity at 20°C not exceeding0.02845 ohm/mm²/m2.Netural Conductor (AAAC Non-Compacted)The neutral shall be an All-Aluminium-Alloy conductor composed of wires drawn from rod, which is manufactured in a continuous casting and rolling procedure. The pr
-
0.6/1kV 3X25+1X54,6mm2 Twisted Alu ABC Aerial Bundled Overhead Cable NF C 33-209
Tensile strength not less than90 N/mm2Resistivity at 20°C not exceeding0.02845 ohm/mm²/m2.Netural Conductor (AAAC Non-Compacted)The neutral shall be an All-Aluminium-Alloy conductor composed of wires drawn from rod, which is manufactured in a continuous casting and rolling procedure. The pr