Cable & Wire

Rubber Cable Insulated and Sheathed for Mining 1kv 3X120mm

YIFANG ELECTRIC GROUP INC.
  • Application:Construction, Underground, Industrial
  • Voltage:Low and Medium Voltage Cable
  • Current:DC & AC
  • Insulation Material:Rubber
  • Sheath Material:Rubber
  • Material Shape:Round Wire

Base Info

  • Model NO.:1kv3x120mm
  • Wire Core Material:Bare Copper Wire
  • Certification:ISO, CCC, CE
  • Model:RC-Be54
  • Brand:Yifang
  • Transport Package:Wooden Drum
  • Specification:1*1.5mm2 to 1*400mm2
  • Trademark:Yifang
  • Origin:China
  • HS Code:85444921
  • Production Capacity:30km Per Month

Description

SpecificationConductor structureConductor diameter
(mm)Conductor package with specifications
(mm)Insulation thickness
(mm)Taping Specifications
(mm)Sheath thickness
(mm)Reference outer diameter
(mm)Reference Weight
(kg/km)1×1.530/0.251.568×0.050.8 1.46.155.61×2.549/0.252.008×0.050.9 1.46.872.41×456/0.302.568×0.051.0 1.57.799.81×684/0.303.5410×0.051.0 1.68.4128.11×1077/0.404.5610×0.201.2 1.811.2206.61×167×18/0.405.5015×0.201.2 1.912.3282.41×257×28/0.407.1015×0.201.4 2.014.5407.01×357×38/0.408.2020×0.201.4 2.216.0521.31×5019×20/0.409.8025×0.201.6 2.418.4714.591×7018×20/0.5011.5030×0.201.6 2.620.5976.941×9519×24/0.5013.4030×0.201.8 2.823.21231.491×12019×30/0.5014.6030×0.201.8 3.024.81554.51×15019×38/0.5016.3030×0.202.0 3.227.31882.01×18537×24/0.5018.5030×0.202.2 3.430.32259.91×24060×20/0.5021.3030×0.202.4 3.533.72941.01×30061×24/0.5024.1030×0.202.6 3.637.13545.41×40061×32/0.5025.5030×0.202.8 3.839.34532.92×1.530/0.251.568×0.050.8 1.59.6133.52×2.549/0.252.008×0.050.9 1.711.4191.92×456/0.302.568×0.051.020×0.201.813.6286.92×684/0.303.548×0.051.020×0.202.015.0429.62×1077/0.404.5610×0.201.230×0.203.122.0848.72×167×18/0.405.5015×0.201.230×0.203.324.21097.82×257×28/0.407.1015×0.201.440×0.203.628.81596.42×357×38/0.408.2020×0.201.440×0.203.931.61980.82×5019×20/0.409.8025×0.201.640×0.204.336.42690.32×7018×20/0.5011.5030×0.201.640×0.204.640.43512.92×9519×24/0.5013.4030×0.201.840×0.205.045.84490.63×1.530/0.251.568×0.050.8 1.610.3159.83×2.549/0.252.008×0.050.9 1.812.2230.0
Operating Property:

 ItemsDescriptionRated Voltage
 Rated voltage 0.45/0.75kV, using the AC system should not be more than 0.9kV.Operating TemperatureThe long-term maxmium operating temperature of cable conductor is 65 ºC. When in short circuit, the maximum temperature is no more than 160 ºC, time of duration is no more than 5 S.
 Environment TemperatureMinimum operating environment temperature is -10 ºC.Laying TemperatureCable laying temperature should be not lower than 0 ºCBending RadiusRecommended minimum bending radius: no more than 10D.StorageFinished cable should be stored at -10~35 ºC, humidity is below 80% of the environment, and avoid direct sunlight and the rain, keep ventilation and dry environment. Keep away from acids, alkalis, mineral oils etc.. According to the above requirements for storage and use, the cable can be used for more than 2 years long.Installation InstructionWhen installed, the environment temperature should not be lower than -10 ºC. if the environment temperature is lower 0 ºC, the cable should be preheated before installation. To avoid the machnical damage of the internal cable, the bending radius of multi-cores cable is not more than10D. ("D "means the out diameter of cable)
SERVICING
 
Purpose:
To establish and maintain a procedure for performing and verifying that our service meets specified requirements and that a suitable method of feedback exists from the customer back to the appropriate individual or department within YIFANG.
 
Scope:
YIFANG does not currently have any contracts that obligate the company to provide installation or service above and beyond normal product service and delivery.  Service activity not specified by contract (such as the treatment of a customer complaint) shall be determined and performed free of charge on a case by case basis. Service concerns will be recorded and will provide a feed-back system as required by the customer.
be determined and performed free of charge on a case by case basis. Service concerns will be recorded and will provide a feed-back system as required by the customer.