
SIP-2 SIP-4 Wire Aluminum Self-Supporting Aerial Bundled Conductor Service Cables
Henan Hongda Cable Co., Ltd.- Type:Insulated
- Conductor Type:Stranded
- Application:Overhead
- Conductor Material:Aluminum
- Sheath Material:Crosslinking
- Insulation Material:XLPE , PE
Base Info
- Model NO.:SIP-1 SIP-2 SIP-3 SIP-4
- Material Shape:Round Wire
- Range of Application:for Overhead Transmission Lines
- Certification:ISO9001, CCC, SGS
- Brand:Hongda
- Rated Voltage:600,1000V, 20kv, 35kv
- Service:OEM, ODM
- Transport Package:1000m Per Drum, 4000m Per Drum
- Specification:2x16mm2, 4x16mm2, 2x25mm2, 4x25mm2
- Trademark:Hongda, or OEM
- Origin:China
- HS Code:8544492100
- Production Capacity:25000km,Year
Description
Nominal cross-section of phase core
mm2Number of wires in the core
units. Outer diameter of conducting core
mm Electrical resistance of 1 km of phase core to DC, ohm not more Min. Max. 16 7 4,6 5,1 1,910 25 7 5,7 6,1 1200 35 7 6,7 7,1 0,868 50 7 7,85 8,35 0,641 70 7 9,45 9,95 0,443 95 7 11,1 11,7 0,320 120 19 11,1 13,1 0,253 150 19 14,0 14,5 0,206 185 19 15,45 16,15 0,164 240 19 17,75 18,45 0,125
2. NEUTRAL MESSENGING CORE - form Al alloy, round core, stranded from round wires,
compacted. Nominal cross-sections, number of wires in the core, outer diameter of core, its burst capacity and electrical resistance are specified in the bellow table:Nominal cross-section of phase core
mm2Number of wires in the core
units. Outer diameter of conducting core
mm Electrical resistance of 1 km of phase core to DC, ohm not more Min. Max. 25 7 5,7 6,1 1,380 35 7 6,7 7,1 0,986 50 7 7,85 8,35 0,720 54,6 7 9,2 9,6 0,630 70 7 9,45 9,95 0,493 95 7 11,1 11,7 0,363 120 19 12,2 12,9 0,288 150 19 13,9 14,5 0,236 185 19 15,75 16,15 0,188 240 19 17,75 18,45 0,145
3. INSULATION - in SIP-1 the neutral core is not insulated. In other conductors the insulation made from light-stabilized cross-linked PE. Insulated phase cores have the distinctive coloring. Insulation thickness is shown in the following table:Types of wire
Nominal isulation thickness, mm 16 25 35 50 54,6 70 95 120 150 185 240 SIP-1 1,3 1,3 1,3 1,5 1,5 1,7 1,7 1,7 1,7 1,9 1,9 SIP-2 SIP-3 20 kV 2,3 SIP-3 35 kV 3,5 SIP-4 1,3 1,3 
APPLICATION
SIP-1 - for overhead transmission lines (TL) and linear TL deviations in atmosphere types I and II as per GOST 15150-69
SIP-2 - for overhead transmission lines (TL) and linear TL deviations in atmosphere types I and II as per GOST 15150-69 , including sea coasts, salt lakes shores, in industrial areas
SIP-3 - for TL with nominal voltage 10-35 kV in atmosphere types II and III as per GOST 15150-69 , including sea coasts, salt lakes shores, in industrial areas
SIP-4 - for TL deviations to entry and for laying in walls of buildings and engineering structures in
atmosphere types II and III as per GOST 15150-69
SIP-1 0,6 / 1 kV1х16+1х25 15 135 3х16+1х25 22 270 3х25+1х35 26 390 3х35+1х50 30 530 3х50+1х50 32 685 3х50+1х70 35 740 3х70+1х70 37 930 3х70+1х95 41 990 3х95+1х70 41 1190 3х95+1х95 43 1255 3х120+1х95 46 1480 3х150+1х95 48 1715 3х185+1х95 52 2330 3х240+1х95 56 2895 SIP-2 0,6 / 1 kV 3х16+1х25 24 308 3х16+1х54,6* 28 427 3х25+1х35 27 424 3х25+1х54,6* 30 512 3х35+1х50 31 571 3х35+1х54,6* 32 606 3х50+1х50 34 727 3х50+1х54,5* 35 762 3х50+1х70 36 798 3х70+1х54,6* 39 973 3х70+1х70 40 1010 3х70+1х95 41 1087 3х95+1х70 43 1240 3х95+1х95 45 1319 3х120+1х95 48 1553 3х150х1х95 50 1787 3х185+1х95 55 2403 3х240+1х95 60 2968 SIP-3 20 kV 1х35 12 165 1х50 13 215 1х70 15 282 1х95 16 364 1х120 18 445 1х150 19 540 1х185 24 722 1х240 24 950 SIP-3 20 kV 1х35 14 209 1х50 16 263 1х70 17 334 1х95 19 421 1х120 20 518 1х150 22 618 1х185 24 808 1х240 26 1045 SIP-4 0,6/1 kV 2х16 15 139 4х16 18 278 2х25 17 196 4х25 21 392


More question and inquiry, please contact with Vivian Yuan,
phone number: +86-15838290725.
mm2
units.
mm
2. NEUTRAL MESSENGING CORE - form Al alloy, round core, stranded from round wires,
compacted. Nominal cross-sections, number of wires in the core, outer diameter of core, its burst capacity and electrical resistance are specified in the bellow table:Nominal cross-section of phase core
mm2
units.
mm
3. INSULATION - in SIP-1 the neutral core is not insulated. In other conductors the insulation made from light-stabilized cross-linked PE. Insulated phase cores have the distinctive coloring. Insulation thickness is shown in the following table:Types of wire

APPLICATION
SIP-1 - for overhead transmission lines (TL) and linear TL deviations in atmosphere types I and II as per GOST 15150-69
SIP-2 - for overhead transmission lines (TL) and linear TL deviations in atmosphere types I and II as per GOST 15150-69 , including sea coasts, salt lakes shores, in industrial areas
SIP-3 - for TL with nominal voltage 10-35 kV in atmosphere types II and III as per GOST 15150-69 , including sea coasts, salt lakes shores, in industrial areas
SIP-4 - for TL deviations to entry and for laying in walls of buildings and engineering structures in
atmosphere types II and III as per GOST 15150-69
SIP-1 0,6 / 1 kV


More question and inquiry, please contact with Vivian Yuan,
phone number: +86-15838290725.
