2X0.50+10X0.22mm Security Alarm Cable
Cable construction :Party 1Conductor:2×(16/0.20mm)TC/BC/CCA/TCCADielectric:Type: PVCDiameter: 1.50mmColor Code:1.Blk2.RedParty 2Conductor:10×(7/0.20mm)TC/BC/CCA/TCCADielectric:Type: PVCDiameter: 0.95mmColor Code:1.Blk2.Red3.Ylw4.Grn5.Brn6.Blu7.Wht8.Org9.Ppl10.GryRip CordCotton WireJacket
-
2X0.50+8X0.22mm Security Alarm Cable
Cable construction :Party 1Conductor:2×(16/0.20mm)TC/BC/CCA/TCCADielectric:Type: PVCDiameter: 1.50mmColor Code:1.Blk2.RedParty 2Conductor:8×(7/0.20mm)TC/BC/CCA/TCCADielectric:Type: PVCDiameter: 0.95mmColor Code:1.Blk2.Red3.Ylw4.Grn5.Brn6.Blu7.Wht8.OrgRip CordCotton WireJacket:Type: PVCDi
-
2X0.22mm Security Alarm Cable
Cableconstruction:Conductor:2x(7/0.20mmTC/BC/CCA/TCCA)Dielectric:Type:PVCDiameter:0.95mmColorCode:1.Blk2.RedRipCordCottonWireJacket:Type:PVCDiameter:3.00mmPrintLegend:0.22mm²2CUnshieldedSecurityAlarmCable×××MElectricalProperties:TemperatureRating(-20ºC~+60ºC)Operatin
-
6X0.22mm Security Alarm Cable
Cable construction :Conductor:6 x (7/0.20mm TC/BC/CCA/TCCA)Dielectric:Type: PVCDiameter: 0.95mmColor Code:1.Blk2.Red3.Ylw4.Grn5.Brn6.BluShield:Aluminum FoilDrain Wire7 x 0.20mm (TC/BC/CCA/TCCA)Rip CordCotton WireJacket:Type: PVCDiameter: 4.20mmPrint Legend:0.22mm² 6C Shielded Security Alarm Cab
-
3X1.0mm2 Fire Alarm Cable
Cable construction :Conductor:Solid Bare Copper 3×1.13mmInsulation:Type:PVC-FPLRDia.over Dielectric: 0.086''nom.(2.2mm)Insulation Color:Blu/BrnSeparator :PET FoilDrain Wire:0.8mm Aluminum/TCCAShield:Aluminum PET (100% Coverage 20% overlapping)Jacket:PVC-FPLRDia.over Jacket: 0.252''(6.4mm)Alarm
-
SAT703 Coaxial Cable
5) Min.Structural Return Loss (5-3000MHz) : 20 dB6) Max. Attenuation :@Frequency (MHz)dB/100 ft (MAX.)dB/100 meters(MAX)5 MHz0.58 dB1.90 dB55 MHz1.60 dB5.25 dB211 MHz1.95 dB10.00 dB250 MHz2.85 dB10.82 dB270 MHz3.05 dB11.04 dB300 MHz3.30 dB11.64 dB330 MHz3.55 dB12.26 dB350 MHz3.85 dB12.63 dB400 MHz4.
-
Rg6u Coax Cable
5) Min.Structural Return Loss (5-3000MHz) : 20 dB6) Max. Attenuation :@Frequency (MHz)dB/100 ft (MAX.)dB/100 meters(MAX)5 MHz0.58 dB1.90 dB55 MHz1.60 dB5.25 dB211 MHz1.95 dB10.00 dB250 MHz2.85 dB10.82 dB270 MHz3.05 dB11.04 dB300 MHz3.30 dB11.64 dB330 MHz3.55 dB12.26 dB350 MHz3.85 dB12.63 dB400 MHz4.
-
AAC Bare Conductor 19/1.80 mm conductor IEC 61089 for Distribution Line
kNDC.20°CΩ/km1071.3510.024.0527.41.952.86331671.7116.085.1243.83.041.78962572.1324.946.4068.44.501.14534072.7040.088.09109.46.800.71586373.3963.1810.20172.310.390.4545100192.59100.1012.90274.817.000.2877125192.89124.6314.50343.621.250.2302160193.27159.5716.40439.826.400.1798200193.66199.90