Cable & Wire

Electrical Wireb Power Cable Electrical Cable and Copper Conductor PVC Sheath Wire

Zhejiang Kuayue Cable Co., Ltd.
  • Application:Construction, Overhead, Underground, Power Station
  • Voltage:Low and Medium Voltage Cable
  • Current:AC Cable
  • Insulation Material:PVC
  • Sheath Material:PVC
  • Material Shape:Flat Wire

Base Info

  • Model NO.:power cable
  • Wire Core Material:Bare Copper Wire
  • Certification:ISO, CCC, CE, RoHS
  • Model:YJV
  • Brand:Hanli
  • Transport Package:100m
  • Specification:30x30x6cm
  • Trademark:hanli
  • Origin:Zhejiang
  • Production Capacity:2000000m,Month

Description

Size of conductorNominal thickness of insulation


mmMean overall diameter

Upper limit

mmApprox. Net weight per km



KgNominal
Cross-sectional area

mm2Number and diameter of wires
No. /mm1.032/0.200.63.0161.530/0.250.73.5212.550/0.250.84.233456/0.300.84.850684/0.300.86.3701080/0.401.07.612016126/0.401.08.817525196/0.401.211.029035276/0.401.212.540050396/0.401.414.556570360/0.501.417.077095475/0.501.619.01010120608/0.501.621.01260150756/0.501.823.51580185925/0.502.026.019002401221/0.502.229.52500
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. 
2. Colors of standard: Red, black, brown, grey, orange, white, violet, pink, green/yellow, yellow

300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6243y
Three-core (Flat) with Bare
Earth-continuity Conductor Size of conductorNominal thickness
Of insulation




mmSize of
Earth-
Conduct
-ivity
Conductor



No/mmNominal thickness
Of sheath





mmMean overall dimensionsApprox. Net weight per km





KgNominal
Cross-
Sectional area

mm2Number and diameter of wires

mmLower limit



mmUpper
Limit



mm1.01/1.130.61/1.130.94.0*9.64.7*11.0921.51/1.380.71/1.130.94.4*10.55.4*12.51152.51/1.780.81/1.131.05.2*12.56.2*14.517047/0.850.81/1.381.15.8*14.57.4*18.025567/1.040.81/1.781.16.4*16.58.0*20.0340107/1.351.07/0.851.27.8*21.09.6*25.5550167/1.701.07/1.041.39.0*24.511.0*29.5790
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Red, yellow and blue(yellow in centre) Sheath colors: Grey or white. 

300/300V PVC Insulated Parallel Flexible Cords to BS 6500
Reference No 2812X RVB
Twin Core Size of conductorNominal
Thickness
Of insulation


mmMean overall dimensionsApprox. Net weight per km




KgNominal
Cross-sectional area

mm2Number and diameter of wires

No/mmLower
Limit


mmUpper
Limit


mm0.528/0.150.82.5X5.03.0X6.0240.7542/0.150.82.7X5.43.2X6.429
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound. 
2. One core with a ridge for identification. 


300/500V and 450/750V PVC Insulated Flexible Cords to BS 6500/6004
Reference No 2491X
Single Core Size of conductorNominal
Thickness
Of insulation

mmMean overall diameter

Upper limit

mmApprox. Net weight per km



KgNominal
Cross-sectional area

mm2Number and diameter of wire

No/mm0.516/0.200.62.6100.7524/0.200.62.8131.032/0.200.63.0161.5*30/0.250.73.5202.5*50/0.250.84.2324.0*56/0.300.84.849
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. 
2. Standard colors: Red. Black, white, blue, brown, grey and green/yellow. 
*: Rating Voltage 450/750V

300/500V PVC Insulated Twisted Twin Flexible Cords to BS 6500
Reference No 2492X
Twisted Twin Size of conductorNominal
Thickness
Of insulation


mmMean overall diameter of
Each core
Upper limit

mmApprox. Net weight per km


KgNominal
Cross-sectional area

mm2Number and diameter of wires
mm0.516/0.200.64.6200.7524/0.200.65.0261.032/0.200.65.433
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. 
2. Two cores twisted together. 


300/300V PVC Insulated PVC Sheathed Parallel Twin Light Flexible Cords to BS 6500
Reference No 2192Y
Parallel Twin Size of conductorNominal
Thickness
Of insulation



mmNominal
Thickness
Of sheath




mmMean overall dimensionsApprox. Net weight per km




KgNominal
Cross-
Sectional area

mm2Number and diameter of wires

No. /mmUpper
Limit



mmUpper
Limit



mm0.516/0.200.50.63.0X4.83.6X6.0270.7524/0.200.50.63.2X5.23.9X6.434
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Blue and brown. Sheathed colors: Grey, white or black. 

300/300V PVC/PVC Sheathed Circular Light Flexible Cords to BS 6500
Reference No 2182Y
Twin Core Size of conductorNominal
Thickness
Of insulation


mmNominal
Thickness
Of sheath



mmMean overall dimensionsApprox. Net weight per km




KgNominal
Cross-
Sectional
Area
mm2Number and diameter of wires
No. /mmUpper
Limit


mmUpper
Limit


mm0.516/0.200.50.64.86.0360.7524/0.200.50.65.26.445
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Blue and brown. Sheathed colors: Grey, white or black. 


Reference No 2183Y
Three Core Size of conductorNominal
Thickness of insulation



mmNominal
Thickness of
Sheath



mmMean overall dimensionsApprox. Net weight per km




KgNominal
Cross-
Sectional area

mm2Number and diameter of wires

No/mmLower
Limit



mmUpper
Limit



mm0.516/0.20.50.65.06.2440.7524/0.20.50.65.46.855
Notes
1. Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Green/ yellow blue and brown. Sheathed colors: Grey, white or black. 

300/500V PVC/PVC Sheathed Parallel Twin Flexible Cords to BS 6500
Reference No 3192Y
Parallel Twin Size of conductorNominal
Thickness of insulation


mmNominal thickness of
Sheath


mmMean overall dimensionsApprox. Net weight per km



KgNominal
Cross-
Sectional area
mm2Number and diameter of wires
No. /mmLower
Limit


mmUpper
Limit


mm0.7524/0.200.60.83.8*6.05.2*7.647
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Blue and brown. Sheathed colors: Grey white or black. 


300/500VPVC/PVC Sheathed Circular Flexible Cords to BS 6500
Reference No 3182Y
Twin Core Size of conductorNominal
Thickness of insulation



mmNominal
Thickness of
Sheath



mmMean overall dimensionsApprox. Net weight per km




KgNominal
Cross-
Sectional
Area

mm2Number and diameter of wires

No/mmLower
Limit



mmUpper
Limit



mm0.7524/0.200.60.86.07.6631.032/0.200.60.86.48.0731.2540/0.200.70.87.08.6841.530/0.250.70.87.49.0952.550/0.250.81.08.911.0145
Notes
1. Conductors of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound. 
2. Core colors: Blue and brown. Sheathed colors: Grey. White or black. 
Electrical Wireb Power Cable Electrical Cable and Copper Conductor PVC Sheath Wire

Electrical Wireb Power Cable Electrical Cable and Copper Conductor PVC Sheath Wire
Electrical Wireb Power Cable Electrical Cable and Copper Conductor PVC Sheath Wire
Electrical Wireb Power Cable Electrical Cable and Copper Conductor PVC Sheath Wire
Electrical Wireb Power Cable Electrical Cable and Copper Conductor PVC Sheath Wire
Electrical Wireb Power Cable Electrical Cable and Copper Conductor PVC Sheath Wire


Q1. What kind of products can your company supply?
 A: We specialize in supplying network cable, coaxial cable, fiber optical cable, telephone cable, speaker cable and etc. 
 
Q2. What's your MOQ?
A: The MOQ of long meter cable is 50 km, or we can negociate. 
 
Q3. What's your delivery time? 
A: Our delivery time is about 15-20 days after comfriming the deposite, it is based on the quantity of the order.
 
Q4. What are your payment terms?
A: Normally, we accept T/T in advance, as for other payment term, we can negociate with you.
 
Q5. What's your trade term ? 
A: We can accept FOB, CIF term.  
 
Q6. What's your conventional packing ?
A: 100m/plastic or wooden drum, 305m/wooden drum or color box. However, we can produce according your demand.
 
Q7. Can your factory customize cables based on clients' samples or data sheet ? 
 A: Yes, we can. 


  

Conductors of high conductivity copper wires, insulated with PVC compound, two cores twisted together.